VALAN ROSS MARTINI
Pilots at Creekview Ter, Alpharetta, GA

License number
Georgia A4398891
Category
Airmen
Type
Authorized Aircraft Instructor
Address
Address
330 Creekview Ter, Alpharetta, GA 30005

Personal information

See more information about VALAN ROSS MARTINI at radaris.com
Name
Address
Phone
Valan Martini, age 66
330 Creekview Ter, Alpharetta, GA 30005
(229) 387-8679
Valan R. Martini
Atlanta, GA
(770) 664-0855
Valan R Martini, age 66
330 Creek View Ct, Alpharetta, GA 30005
(770) 664-0855

Professional information

Valan Martini Photo 1

Energy Saving System And Method For Cooling Computer Data Center And Telecom Equipment

US Patent:
2013028, Oct 31, 2013
Filed:
Jun 26, 2013
Appl. No.:
13/928132
Inventors:
Valan R. MARTINI - Alpharetta GA, US
International Classification:
H05K 7/20
US Classification:
361695, 361690
Abstract:
A system and method of reducing consumption of electricity used to cool electronic computer data center, networking, and telecommunications equipment, and to reduce the incidence of thermal failure of electronic components, includes provision of one or more partitions to reduce the volume of the cooled environment supplying coldest possible cooled air from air conditioning systems to a chamber adjacent to racks containing the electronic components, preventing dilution of the supplied cooling airflow by warmer air from outside of the reduced volume environment, and controlling the delivery of cooling air flow through the reduced volume of the cooled environment.


Valan Martini Photo 2

Energy Saving System And Method For Cooling Computer Data Center And Telecom Equipment

US Patent:
2009016, Jul 2, 2009
Filed:
Jun 15, 2007
Appl. No.:
12/304534
Inventors:
Valan R. Martini - Alpharetta GA, US
International Classification:
H05K 7/20
US Classification:
361691, 361694, 361695, 622592, 62419
Abstract:
A system and method of reducing consumption of electricity used to cool electronic computer data center, networking, and telecommunications equipment, and to reduce the incidence of thermal failure of electronic components, includes provision of one or more partitions to reduce the volume of the cooled environment supplying coldest possible cooled air from air conditioning systems to a chamber adjacent to racks containing the electronic components, preventing dilution of the supplied cooling airflow by warmer air from outside of the reduced volume environment, and controlling the delivery of cooling air flow through the reduced volume of the cooled environment.