TRACEY T LEMMON
Plumbers at Youngs Grv Rd, Columbus, OH

License number
Ohio HV.25481
Effective Date
Apr 1, 2017
Expiration Date
Mar 31, 2018
Type
HVAC Contractors
Address
Address
2678 Youngs Grove Rd, Columbus, OH 43231
Phone
(614) 818-9141

Organization information

See more information about TRACEY T LEMMON at bizstanding.com

Lemmco LLC

2678 Youngs Grv Rd, Columbus, OH 43231

Status:
Inactive
Industry:
Whol Petroleum Products, Electrician, Generator Installers, ...
Registration:
1971
Phone:
(800) 583-3575 (Phone)
Description:
At Lemmco, LLC., we have been helping businesses find innovative solutions to soaring energy costs in 10 states and Mexico for over 40 years. Our systems benefit small users and large industrial and u...
Principals:
Tracey Lemon,Tracey T. Lemmon Principal, inactive
Features:
Emergency Service
Licensed:
Yes
Service area:
Midwest States
Free estimates:
Yes
Senior discount:
No
Warranties:
Ask for details
Open Hours:
Mon - Fri 8:00 AM - 5:00 AM, By Appointment

Professional information

Tracey Lemmon Photo 1

Owner, Lemmco L.l.c.

Position:
Owner at Lemmco L.L.C.
Location:
Columbus, Ohio Area
Industry:
Construction
Work:
Lemmco L.L.C. - Owner
Education:
Universtiy of Michigan, Flint and Florida Atlantic Universtiy
Skills:
Construction


Tracey Lemmon Photo 2

System And Method For Controlling A Hazardous Fluid Distribution Facility

US Patent:
6827112, Dec 7, 2004
Filed:
Oct 15, 2003
Appl. No.:
10/686244
Inventors:
Tracey T. Lemmon - Columbus OH 43231
International Classification:
B65B 104
US Classification:
141 98, 141 51, 141 94, 141197, 141285, 141DIG 2
Abstract:
System for controlling a hazardous fluid distribution facility wherein a control arrangement is provided at the facility having a power on switch providing for its general energization and de-energization along with a start switch which is actuated by an operator for an interval of time sufficient for a gas pressure control monitor to assume an enable condition causing the actuation of tank valves and the enablement of emergency shut-off valves. A receiver is incorporated with the housing which performs in conjunction with strategically positioned emergency transmitters which are actuated by personnel in the event of a perceived emergency condition. The transmitters transmit an off-state signal which is responded to by the receiver circuit to vent the pneumatic actuation and enablement system as well as to disenable electrical input to pump motors. The transmitters are polled periodically by the receiver circuit to determine their operational status.


Tracey Lemmon Photo 3

System And Method For Controlling A Hazardous Fluid Distribution Facility

US Patent:
2003010, Jun 5, 2003
Filed:
Dec 4, 2001
Appl. No.:
10/000068
Inventors:
Tracey Lemmon - Columbus OH, US
International Classification:
B65B003/04, B65B001/04
US Classification:
141/001000
Abstract:
System and method for controlling a hazardous fluid distribution facility wherein a control arrangement is provided at the facility having a power on switch providing for its general energization and de-energization along with a start switch which is actuated by an operator for an interval of time sufficient for a gas pressure control monitor to assume an enable condition causing the actuation of tank valves and the enablement of emergency shut-off valves. A receiver is incorporated with the housing which performs in conjunction with strategically positioned emergency transmitters which are actuated by personnel in the event of a perceived emergency condition. The transmitters transmit an off-state signal which is responded to by the receiver circuit to vent the pneumatic actuation and enablement system as well as to disenable electrical input to pump motors. The transmitters are polled periodically by the receiver circuit to determine their operational status.