PAUL E MARTIN
Plumbers in Salem, NH

License number
Massachusetts 12380
Issued Date
Oct 18, 1995
Expiration Date
May 1, 2018
Type
Master Plumber
Address
Address
Salem, NH 03079

Personal information

See more information about PAUL E MARTIN at radaris.com
Name
Address
Phone
Paul St Martin, age 52
492 Walpole Valley Rd, Alstead, NH 03602
(603) 756-3949
Paul St Martin, age 58
49 Adams Rd, Londonderry, NH 03053
(603) 434-8048

Organization information

See more information about PAUL E MARTIN at bizstanding.com

PAUL E. MARTIN PLUMBING & HEATING, INC

Salem, NH

Industry:
Heating & Air Conditioning/hvac, Plumbing
Doing business as:
Paul E Martin Plumbing & Heating Inc
Registration:
Nov 9, 2007
Phone:
(603) 893-6954 (Phone)
Description:
Your comfort is our number one priority! When your heating system goes out, we’ll be there. Or if you’re thinking about remodeling your bathroom or kitchen, we can help you with that too. Paul E. Mar...
Addresses:
6 Meridian Dirve, Salem, NH 03079 (Physical)
6 Meridian Dr, Salem, NH 03079 (Physical)
State ID:
000964382
Business type:
Foreign Corporation
Secretarys:
Paul E. Martin (President), 6 Meridian Dr, Salem, NH 03079 (Physical),Kellie Martin (Treasurer), 6 Meridian Dr, Salem, NH 03079 (Physical),Paul E Martin (Secretary), 6 Meridian Dr, Salem, NH 03079 (Physical)
Agent:
Scott Martin,500 Jackson St, Methuen, MA 01844 (Physical)
Licensed:
Yes
Service area:
Merrimack Valley and Southern New Hampshire
Free estimates:
Yes
Senior discount:
No
Excluded services:
Cooling
Warranties:
1 Year
Open Hours:
Mon-Fri 8:00 AM-4:00 PM; Sat-Sun Closed

Professional information

Paul Martin Photo 1

Above-Ground And In-Ground Fertilizer And Irrigation Apparatus

US Patent:
6540156, Apr 1, 2003
Filed:
May 16, 2001
Appl. No.:
09/858940
Inventors:
Paul E. Martin - Salem NH 03079
International Classification:
B25B 726
US Classification:
239310, 239317, 239318, 239207, 405 36
Abstract:
A fertilizer and irrigation apparatus includes an inflow pipe, a shunt pipe connected to the inflow pipe, and a chemical additive assembly connected in parallel to the shunt pipe. An outflow pipe is also connected to the shunt pipe. A portion of the inflow pipe, the shunt pipe, the chemical additive assembly, and the outflow pipe are all above ground. The chemical additive assembly includes a quantity of a chemical additive. A manifold is connected to the outflow pipe. A plurality of in-ground distribution conduits are connected to the manifold, wherein each of the distribution conduits includes at least one above-ground sprinkler head. In addition, an auxiliary inflow assembly can be connected to the inflow pipe so that chemical additives can be supplied to the fertilizer and irrigation apparatus from an outside source.