Matthew Todd Giaraffa
Engineers at Cedar Ave, Denver, CO

License number
Colorado 50760
Issued Date
Dec 15, 2015
Renew Date
Dec 15, 2015
Expiration Date
Oct 31, 2017
Type
Professional Engineer
Address
Address
7831 E Cedar Ave, Denver, CO 80230

Personal information

See more information about Matthew Todd Giaraffa at radaris.com
Name
Address
Phone
Matthew Giaraffa
7831 E Cedar Ave, Denver, CO 80230

Professional information

Matthew Giaraffa Photo 1

Method And Apparatus For Thermal Control Of A Multiple Chamber Test System

US Patent:
2013003, Feb 7, 2013
Filed:
Oct 1, 2010
Appl. No.:
12/896254
Inventors:
James A. Provost - Westminster CO, US
Matthew Giaraffa - Denver CO, US
Wendell KR Hutchings - Aurora CO, US
Assignee:
Qualmark Corporation - Denver CO
International Classification:
G01M 7/02
US Classification:
73665
Abstract:
A multiple chamber test system is provided. The multiple chamber test system includes a plurality of test chambers that each include a vibration table. In addition, each of the test chambers is provided with thermally controlled air from a common source. An output plenum for providing thermally controlled air to the test chambers may include a flow control device, to provide the same or similar thermal conditions in each of the test chambers. Where pneumatic actuators are used to impart movement to the vibration tables, the exhaust air from the actuators can be prevented from mixing with the thermally controlled chamber air.


Matthew Giaraffa Photo 2

Method And Apparatus For Thermal Control Of A Multiple Chamber Test System

US Patent:
8616063, Dec 31, 2013
Filed:
Aug 12, 2011
Appl. No.:
13/209136
Inventors:
James A. Provost - Westminster CO, US
Matthew Giaraffa - Denver CO, US
Wendell K R Hutchings - Aurora CO, US
Assignee:
Qualmark Corporation - Denver CO
International Classification:
G01N 7/06, G01N 17/00
US Classification:
73663, 738656
Abstract:
A multiple chamber test system is provided. The multiple chamber test system includes a plurality of test chambers that each include a vibration table. In addition, each of the test chambers is provided with thermally controlled air from a common source. An output plenum for providing thermally controlled air to the test chambers may include a flow control device, to provide the same or similar thermal conditions in each of the test chambers. Where pneumatic actuators are used to impart movement to the vibration tables, the exhaust air from the actuators can be prevented from mixing with the thermally controlled chamber air.