DR. LINDSEY R ROLSTON, M.D
Medical Practice in Millville, IN

License number
Indiana 01041311
Category
Medical Practice
Type
Orthopaedic Surgery
Address
Address
2200 Forest Ridge Pkwy Suite #240, Millville, IN 47362
Phone
(765) 521-7385
(765) 521-7394 (Fax)

Organization information

See more information about LINDSEY R ROLSTON at bizstanding.com

Lindsey R Rolston MD

2200 Frst Rdg Pkwy, Millville, IN 47362

Industry:
Medical Doctor's Office, Orthopedics, Sports Medicine
Doing business as:
Lindsey Rolston MD
Phone:
(765) 521-7385 (Phone)
Medical Doctor, Principal:
Lindsey Rolston Medical Doctor, Principal, inactive

Professional information

Lindsey R Rolston Photo 1

Dr. Lindsey R Rolston, New Castle IN - MD (Doctor of Medicine)

Specialties:
Orthopedic Surgery
Address:
New Castle Clinic
1007 N 16Th St, New Castle 47362
(765) 529-0780 (Phone)
2200 Forest Ridge Pkwy, New Castle 47362
Medical Specialties
110 E 13Th St, Rushville 46173
(765) 932-7536 (Phone)
Certifications:
Orthopedic Surgery, 1996
Awards:
Healthgrades Honor Roll
Languages:
English
Hospitals:
New Castle Clinic
1007 N 16Th St, New Castle 47362
2200 Forest Ridge Pkwy, New Castle 47362
Medical Specialties
110 E 13Th St, Rushville 46173
Henry County Memorial Hospital
1000 North 16Th St, New Castle 47362
Education:
Medical School
University of Illinois At Chicago / College of Medicine
Graduated: 1989
Affiliations:
International Congress for Joint Reconstruction, Member
The International Congress for Joint Reconstruction (ICJR) delivers continuing medical education to orthopedic surgeons focused on the latest operative techniques, procedures, advanced devices, and improvements in patient care. Physicians affiliated with ICJR are committed to offering patients the best treatment options available today


Lindsey Rolston Photo 2

Physician At Hospital

Position:
physician at hospital
Location:
New Castle, Indiana
Industry:
Medical Practice
Work:
hospital since Jul 1994 - physician
Education:
MSU/KCMS 1989 - 1994
University of Illinois at Urbana-Champaign 1985 - 1989
Doctor of Medicine (M.D.)
Bradley University 1981 - 1985
Bachelor of Applied Science (B.A.Sc.), Biology, General
GENOA-KINGSTON HIGH SCHOOL 1977 - 1981
Interests:
GOLF, BASKETBALL
Honor & Awards:
BRADLEY UNIVERSITY ORVILLE NOTHDURFT LIFETIME ACHIEVEMENT AWARD 5/3/11 BRADLEY UNIVERSITY CENTURIAN SOCIETY


Lindsey Ryan Rolston Photo 3

Lindsey Ryan Rolston, New Castle IN

Specialties:
Orthopaedic Surgery, Pediatric Orthopaedic Surgery
Work:
Henry County Center For Orthopedic
2200 Forest Ridge Pkwy, New Castle, IN 47362 New Castle Clinic Inc
2200 Forest Ridge Pkwy, New Castle, IN 47362 Henry County Memorial Hospital
1000 N 16Th St, New Castle, IN 47362 New Castle Clinic Inc
1007 N 16Th St, New Castle, IN 47362 Reid Hospital & Health Care Services
1100 Reid Pkwy, Richmond, IN 47374 New Castle Clinic Inc
110 E 13Th St, Rushville, IN 46173
Education:
University of Illinois at Chicago (1989)


Lindsey Rolston Photo 4

Device And Method For Bicompartmental Arthroplasty

US Patent:
2005017, Aug 4, 2005
Filed:
Mar 25, 2005
Appl. No.:
11/089826
Inventors:
Lindsey Rolston - New Castle IN, US
International Classification:
A61F002/38
US Classification:
623020190, 623020300, 623020350
Abstract:
Disclosed is a device and method of bicompartmental arthroplasty of the knee. The device permits arthroplasty of the medial or lateral and patellofemoral compartments of the knee while leaving the opposite compartments and the anterior and posterior cruciate ligaments intact. The device provides a femoral prosthesis component that includes a trochlear surface and a tibial prosthesis component which can be secured to the tibia. The femoral component is essentially ā€œuā€ shaped having an anterior leg upon which the trochlear surface is positioned and a posterior leg which engages the posterior surface of the distal end of the femur. The femoral component also has a convex articulating surface which engages a concave articulating surface of the tibial prosthesis component to approximate the articulation of a healthy knee. The patellar prosthesis is applied to the posterior surface of the patella and articulates with the trochlear exterior surface of the femur.


Lindsey Rolston Photo 5

Device And Method For Bicompartmental Arthroplasty

US Patent:
2004016, Aug 26, 2004
Filed:
Feb 20, 2003
Appl. No.:
10/370002
Inventors:
Lindsey Rolston - New Castle IN, US
International Classification:
A61F002/38
US Classification:
623/020140, 623/020210
Abstract:
Disclosed is a device and method of bicompartmental arthroplasty of the knee. The device permits arthroplasty of the medial or lateral and patellofemoral compartments of the knee while leaving the opposite compartments and the anterior and posterior cruciate ligaments intact. The device provides a femoral prosthesis component that includes a trochlear surface and a tibial prosthesis component which can be secured to the tibia. The femoral component is essentially ā€œuā€ shaped having an anterior leg upon which the trochlear surface is positioned and a posterior leg which engages the posterior surface of the distal end of the femur. The femoral component also has a convex articulating surface which engages a concave articulating surface of the tibial prosthesis component to approximate the articulation of a healthy knee.


Lindsey Rolston Photo 6

Device For Unicompartmental Knee Arthroplasty

US Patent:
2012033, Dec 27, 2012
Filed:
Mar 9, 2011
Appl. No.:
13/582820
Inventors:
Lindsey R. Rolston - New Castle IN, US
International Classification:
A61F 2/38
US Classification:
623 2032
Abstract:
A device for unicompartmental arthroplasty of the knee. The device permits arthroplasty of the medial and/or lateral tibial condyle, and allows for securing of the device without the use of bone cement. Such a device comprises a baseplate, the baseplate comprising a first surface configured to be secured to a surgically prepared medial (or lateral) compartment of a proximal end of a patient's tibia, and an opposing second surface configured to replicate a medial (or lateral) tibial condyle; a flange adjacent the baseplate, the flange shaped to interface with a surgically prepared anterior surface of the proximal end of the patient's tibia, the flange comprising an orifice therethrough; and at least one anchor protruding from the first surface, the at least one anchor arranged to coincide with at least one corresponding surgically prepared void in the patient's tibia.