DR. JAMES M CARUSO, MD
Marriage and Family Therapists at Fullerton Ave, Chicago, IL

License number
Illinois 036082576
Category
Osteopathic Medicine
Type
Family Medicine
Address
Address 2
4939 W Fullerton Ave, Chicago, IL 60639
2408 Shaker Ct, Naperville, IL 60564
Phone
(630) 922-4155

Personal information

See more information about JAMES M CARUSO at radaris.com
Name
Address
Phone
James Caruso, age 44
3451 S Emerald Ave, Chicago, IL 60616
(312) 523-3990
James Caruso
41W065 Palomino Dr, Saint Charles, IL 60175
James Caruso
949 E 170Th Pl, South Holland, IL 60473
James Caruso
8 Court Of Fox River Vly, Lincolnshire, IL 60069
(847) 722-4646
James Caruso
PO Box 222, Riverton, IL 62561

Organization information

See more information about JAMES M CARUSO at bizstanding.com

James M Caruso, M D S C

2408 Shaker Ct, Naperville, IL 60564

Industry:
Medical Doctor's Office
Medical Doctor, Principal:
James Caruso (Medical Doctor, Principal)

Professional information

James Caruso Photo 1

Snr Director Design Na Studio

Position:
Snr Director Design, North America Studio at Motorola Mobility
Location:
Greater Chicago Area
Industry:
Design
Work:
Motorola Mobility - Libertyville /Chicago since Dec 2009 - Snr Director Design, North America Studio Motorola Mobility - Chicago, Libertyville Dec 2007 - Dec 2009 - Business Design Lead, CDMA Motorola Aug 2000 - Dec 2007 - Director, Operations and Design Integration Insight Product Development - Greater Chicago Area Aug 1994 - Aug 2000 - Director, Product Development HLB, LLC. - Greater Chicago Area Aug 1988 - Aug 1994 - Senior Designer, Project Manager Hari and Associates - Greater Chicago Area Jun 1986 - Aug 1988 - Designer
Education:
Motorola Sponsored Studio 2007 - 2011
none, Industrial Design/ Marketing
College for Creative Studies 1982 - 1986
BFA, Product Design
Interests:
Fly fishing, my kids interests, and volunteer work.
Honor & Awards:
IDSA Design Strategy Award, Droid RAZR Design Language, 2012


James M Caruso Photo 2

Dr. James M Caruso, Chicago IL - MD (Doctor of Medicine)

Specialties:
Internal Medicine, Emergency Medicine, General Surgery, Vascular Surgery
Address:
James Caruso Medical Center
4939 W Fullerton Ave, Chicago 60639
(773) 417-3644 (Phone), (773) 887-5740 (Fax)
Conditions:
Abdominal Pain, Appendicitis, Diabetes, Foot Care, Gallbladder Disease, General Surgery, Hemorrhoids, Hernias, Internal Medicine, Minimally Invasive Surgery, Skin Cancer, Varicose Veins, Vascular Disease
Certifications:
General Surgery
Awards:
Healthgrades Honor Roll
Languages:
English, Spanish
Education:
Medical School
Autonomous University Of Guadalajara / Faculty Of Medicine
Loyola University Chicago


James Caruso Photo 3

Elastomeric Controller For Endoscopic Surgical Instruments

US Patent:
5355871, Oct 18, 1994
Filed:
Sep 11, 1992
Appl. No.:
7/943514
Inventors:
Paul Hurley - Chicago IL
James F. Caruso - Chicago IL
Assignee:
Dexide, Inc. - Fort Worth TX
International Classification:
A61B 1700, A61M 300
US Classification:
128 20
Abstract:
A body controller is provided for an endoscopic surgical instrument having a cylindrical housing and an instrument body concentrically disposed interior of the housing and moveable between first and second positions. The controller is designed to accommodate and be activated by light grasping and, preferably, compressive application of, a finger or thumb of the human operator to a section which preferably includes a flexible dome-like or other similarly shaped portion which is substantially immediately responsive to the application of the hand of the surgeon or other operator to activate a surgical instrument carried within the housing, such as a retractable needle, or the like, to one position. By withdrawing the finger or thumb of the surgeon from the flexible means, the instrument body may be moved to a second, or original, position.


James Caruso Photo 4

James Caruso - Chicago, IL

Work:
Construction Medicamp
PHYSICIAN ASSISTANT - CERTIFIED
Construction Medicamp - Pekin, IL
PHYSICIAN ASSISTANT - CERTIFIED
Staff Care, Inc - Goldsboro, NC
PHYSICIAN ASSISTANT - CERTIFIED
Wexford, Inc
PHYSICIAN ASSISTANT - CERTIFIED
Staff Care, Inc - Wilson, NC
PHYSICIAN ASSISTANT - CERTIFIED
North Carolina Department of Corrections
PHYSICIAN ASSISTANT - CERTIFIED
EMSA/ Correctional Physician Services, INC
PHYSICIAN ASSISTANT - CERTIFIED
Columbia HCA Medical Center - Hudson, FL
PHYSICIAN ASSISTANT - CERTIFIED
Cook County Department of Corrections - Chicago, IL
PHYSICIAN ASSISTANT - CERTIFIED
Chicago Fire Department
PARAMEDIC/PARAMEDIC OFFICER
Mercy Hospital & Medical Center - Chicago, IL
RESPIRATORY THERAPIST
Education:
NORTHWESTERN COMMUNITY
Diploma in Medical Technician II
CHICAGO CITY WIDE COLLEGE
Associate in Applied Science in Physician Assistant
UNIVERSITY OF ILLINOIS AT CHAMPAIGN - Champaign, IL
B.S. in Psychology


James Caruso Photo 5

Electric Breast Pump

US Patent:
5542921, Aug 6, 1996
Filed:
Nov 4, 1994
Appl. No.:
8/334812
Inventors:
Brenda J. Meyers - Reedsburg WI
Donald W. Herritz - Reedsburg WI
Jean L. Johansen - Reedsburg WI
William B. Hudson - Fremont MI
Randall P. Bell - River Forest IL
Gary F. Prokop - Wheaton IL
James F. Caruso - Chicago IL
James l. Allen - Lake Villa IL
Assignee:
Gerber Products Company - Fremont MI
International Classification:
A61M 106
US Classification:
604 74
Abstract:
A breast pump includes a housing, a suction unit mounted in the housing, a rippled funnel for engaging a mother's breast, and an adapter for interconnecting same. The adapter is configured to sealingly support the funnel, frictionally sealingly support a bottle for collecting milk, and frictionally sealingly engage the housing. The adapter includes a tubular protrusion/stem defining a passageway for communicating air from the bottle to the suction unit to create a vacuum in the bottle. A pair of "O" rings are positioned on the protrusion to sealingly and stably engage the housing. A check valve is located in the protrusion to prevent back flow of milk from the bottle to the suction unit. The housing includes an outer surface defining a hand grip, and vacuum adjustment controls including a wheel for fine vacuum adjustment and a vacuum releasing push bottom are conveniently positioned on the hand grip. The housing includes a shroud that protects the bottle and that forms a stable arrangement that the entire unit will stand upright on a table.


James Caruso Photo 6

Endoscopic Surgical Instrument With Acute Angle Orientation

US Patent:
5472451, Dec 5, 1995
Filed:
Mar 21, 1994
Appl. No.:
8/215014
Inventors:
Michael W. Freitas - North Richard Hills TX
Troy J. Mullens - North Richland Hills TX
Dale H. Brancel - Colleyville TX
Walter B. Herbst - Evanston IL
Paul Hurley - Chicago IL
Thomasz Milewski - Norridge IL
Kim Vollendorf - Lake Villa IL
James F. Caruso - Chicago IL
International Classification:
A61B 1742
US Classification:
606205
Abstract:
An endoscopic surgical instrument is manually manipulatable by a surgical operator. In one embodiment, the instrument provides an alignment between a hand-held grip and a housing whereby an acute angle is formed at the point of intersection of the axis of the housing and the axis of the grip. In another embodiment, the instrument provides a hand-held grip which includes a pivot portion through which the thumb of the operator is received and which may be pivoted laterally in relation to the housing. In another embodiment, the instrument provides up to complete axial rotation of the housing relative to an instrument body housed therein to permit ease of orientation of the housing and/or body during surgery.


James Caruso Photo 7

Window Grill Assembly And Method For Assembling Same

US Patent:
5307599, May 3, 1994
Filed:
Oct 7, 1992
Appl. No.:
7/957161
Inventors:
Walter B. Herbst - Evanston IL
James F. Caruso - Chicago IL
Assignee:
Emco Specialties, Inc. - Des Moines IA
International Classification:
E06B 130, E04C 238
US Classification:
52207
Abstract:
A window grill assembly includes a window frame having a window opening therein. A grill frame is positioned on one side of the window opening, and retaining frame is positioned on the opposite side. The grill frame includes one flange which engages the front surface of the window frame, and the retaining frame also includes a retaining flange which engages the rear surface of the door frame. A second grill flange extends into the window opening and engages a second retaining flange also within the window opening. The second grill flange and the second retaining flange are secured together to hold the grill frame, the window frame, and the retaining frame together.


James Caruso Photo 8

Hand-Held Calorie Computer

US Patent:
D344535, Feb 22, 1994
Filed:
Jun 1, 1993
Appl. No.:
D/008916
Inventors:
James F. Caruso - Chicago IL
Thomas Bajek - Naperville IL
Kurt T. Peterson - Mt. Prospect IL
Assignee:
Muscle Dynamics Fitness Network, Inc. - Torrance CA
US Classification:
D18 6


James Caruso Photo 9

Dispensing Apparatus

US Patent:
D349506, Aug 9, 1994
Filed:
Mar 23, 1993
Appl. No.:
D/006102
Inventors:
James F. Caruso - Chicago IL
Kim D. Vollendorf - McHenry IL
Gregory W. Lantz - Wheaton IL
Walter B. Herbst - Evanston IL
Assignee:
Fluid Management Limited Partnership - Wheeling IL
US Classification:
D15199


James Caruso Photo 10

Electric Breast Pump

US Patent:
D372975, Aug 20, 1996
Filed:
Nov 4, 1994
Appl. No.:
D/030681
Inventors:
Brenda J. Meyers - Reedsburg WI
Donald W. Herritz - Reedsburg WI
Jean L. Johansen - Reedsburg WI
William B. Hudson - Fremont MI
Randall P. Bell - River Forest IL
Gary F. Prokop - Wheaton IL
James F. Caruso - Chicago IL
James L. Allen - Lake Villa IL
Assignee:
Gerber Products Company - Fremont MI
US Classification:
D24109