DR. ELI S GANG, M.D.
Osteopathic Medicine at Camden Dr, Beverly Hills, CA

License number
California G49587
Category
Osteopathic Medicine
Type
Cardiovascular Disease
License number
California G49587
Category
Osteopathic Medicine
Type
Clinical Cardiac Electrophysiology
Address
Address
414 N Camden Dr STE 1100, Beverly Hills, CA 90210
Phone
(310) 278-3400
(310) 278-1240 (Fax)

Organization information

See more information about ELI S GANG at bizstanding.com

Cardiovascular Medical Group - Eli S Gang MD

414 N Camden Dr STE 1100, Beverly Hills, CA 90210

Categories:
Cardiology Physicians & Surgeons, Physicians & Surgeons
Phone:
(310) 278-3400 (Phone)

Professional information

Eli S Gang Photo 1

Dr. Eli S Gang - MD (Doctor of Medicine)

Procedures:
Abdominal Aortic Ultrasound, Pacemakers, Echo Stress Test, Echocardiography, Ablation Therapy, Cardiology, Thallium Stress Test, 24hr Ambulatory Ekg, Defibrillator Implantation, Ekg
Hospitals:
Cardiovascular Medical Group
414 N Camden Dr STE 1100, Beverly Hills 90210
Ronald Reagan UCLA Medical Center
757 Westwood Plz, Los Angeles 90095
Southern California Hospital at Culver City
3828 Delmas Ter, Culver City 90232
Cedars - Sinai Medical Center
8700 West Beverly Blvd, West Hollywood 90048
Cardiovascular Medical Group
414 N Camden Dr STE 1100, Beverly Hills 90210
Ronald Reagan UCLA Medical Center
757 Westwood Plz, Los Angeles 90095
Southern California Hospital at Culver City
3828 Delmas Ter, Culver City 90232
Cedars - Sinai Medical Center
8700 West Beverly Blvd, West Hollywood 90048
Education:
Medical Schools
Columbia University College Of Physicians and Surgeons
Graduated: 1975


Eli S Gang Photo 2

Eli S Gang, Beverly Hills CA

Specialties:
Cardiologist
Address:
414 N Camden Dr, Beverly Hills, CA 90210
Education:
Columbia University, College of Physicians and Surgeons - Doctor of Medicine
New York Presbyterian Hospital-Columbia Presbyterian Center - Fellowship - Cardiology
Board certifications:
American Board of Internal Medicine Certification in Internal Medicine, American Board of Internal Medicine Sub-certificate in Cardiovascular Disease (Internal Medicine)


Eli Gang Photo 3

Apparatus For Magnetically Deployable Catheter With Mosfet Sensor And Method For Mapping And Ablation

US Patent:
2009024, Oct 1, 2009
Filed:
Jun 8, 2009
Appl. No.:
12/480566
Inventors:
Yehoshua Shachar - Santa Monica CA, US
Laszlo Farkas - Ojai CA, US
Eli Gang - Beverly Hills CA, US
Assignee:
Magnetecs, Inc. - Inglewood CA
International Classification:
A61B 18/14, A61B 5/053
US Classification:
606 41, 600547
Abstract:
A mapping and ablation catheter is described. In one embodiment, the catheter includes a MOSFET sensor array that provides better fidelity of the signal measurements as well as data collection and reduces the error generated by spatial distribution of the isotropic and anisotropic wavefronts. In one embodiment, the system maps the change in potential in the vicinity of an activation wavefront. In one embodiment, the mapping system tracks the spread of excitation in the heart, with properties such as propagation velocity changes. In one embodiment, during measurement, the manifold carrying the sensor array expands from a closed position state to a deployable open state. Spatial variation of the electrical potential is captured by the system's ability to occupy the same three-dimensional coordinate set for repeated measurements of the desired site. In one embodiment, an interpolation algorithm tracks the electrogram data points to produce a map relative to the electrocardiogram data.


Eli Gang Photo 4

Apparatus For Magnetically Deployable Catheter With Mosfet Sensor And Method For Mapping And Ablation

US Patent:
7869854, Jan 11, 2011
Filed:
Feb 23, 2006
Appl. No.:
11/362542
Inventors:
Yehoshua Shachar - Santa Monica CA, US
Laszlo Farkas - Ojai CA, US
Eli Gang - Beverly Hills CA, US
Assignee:
Magnetecs, Inc. - Inglewood CA
International Classification:
A61B 5/04
US Classification:
600374
Abstract:
A mapping and ablation catheter is described. In one embodiment, the catheter includes a MOSFET sensor array that provides better fidelity of the signal measurements as well as data collection and reduces the error generated by spatial distribution of the isotropic and anisotropic wavefronts. In one embodiment, the system maps the change in potential in the vicinity of an activation wavefront. In one embodiment, the mapping system tracks the spread of excitation in the heart, with properties such as propagation velocity changes. In one embodiment, during measurement, the manifold carrying the sensor array expands from a closed position state to a deployable open state. Spatial variation of the electrical potential is captured by the system's ability to occupy the same three-dimensional coordinate set for repeated measurements of the desired site. In one embodiment, an interpolation algorithm tracks the electrogram data points to produce a map relative to the electrocardiogram data.