EDWARD ESSER FINE
Medical Practice in Buffalo, NY

License number
Pennsylvania MD041806L
Category
Medicine
Type
Medical Physician and Surgeon
Address
Address 2
Buffalo, NY 14221
Pennsylvania

Personal information

See more information about EDWARD ESSER FINE at radaris.com
Name
Address
Phone
Edward Fine
337 Madison Ave, New Eagle, PA 15067
Edward Fine
404 1St St, Donora, PA 15033
Edward Fine
6626 Beacon St, Pittsburgh, PA 15217
Edward Fine
681 Terrace St, Meadville, PA 16335
Edward Fine
714 Chestnut St, Meadville, PA 16335

Professional information

Edward J Fine Photo 1

Edward J Fine, Buffalo NY

Specialties:
Neurologist
Address:
3495 Bailey Ave, Buffalo, NY 14215
100 High St, Buffalo, NY 14203
300 Essjay Rd, Williamsville, NY 14221
Education:
Ohio State University, College of Medicine - Doctor of Medicine
Brigham & Women's Hospital - Fellowship - Clinical Neurophy
Montefiore Medical Center - Fellowship - Pathology
Rhode Island Hospital - Residency - Neuropathology (Pathology)
Albany Medical Center - Residency - Neurology
Board certifications:
American Board of Psychiatry and Neurology Certification in Neurology (Psychiatry and Neurology), American Board of Psychiatry and Neurology Sub-certificate in Clinical Neurophysiology (Psychiatry and Neurology)


Edward Fine Photo 2

Dr. Edward Fine, Buffalo NY - MD (Doctor of Medicine)

Specialties:
Clinical Neurophysiology
Address:
JACOBS NEUROLOGICAL INSTITUTE
300 Essjay Rd SUITE 100, Buffalo 14221
(716) 932-6080 (Phone)
BUFFALO GENERAL HOSPITAL
100 High St, Buffalo 14203
(716) 859-5600 (Phone), (716) 859-2925 (Fax)
BUFFALO GENERAL HOSPITAL
100 High St, Buffalo 14203
(716) 859-5600 (Phone), (716) 898-5029 (Fax)
3495 Bailey Ave SUITE 901B, Buffalo 14215
(716) 859-7501 (Phone)
VA MEDICAL CENTER
3495 Bailey Ave, Buffalo 14215
(716) 834-9200 (Phone), (716) 834-9200 (Fax)
Jacobs Neurological Institute
300 Essjay Rd SUITE 100, Buffalo 14221
(716) 932-6080 (Phone)
Certifications:
Clinical Neurophysiology, 2003, Neurology, 1976
Awards:
Healthgrades Honor Roll
Languages:
English
Hospitals:
JACOBS NEUROLOGICAL INSTITUTE
300 Essjay Rd SUITE 100, Buffalo 14221
BUFFALO GENERAL HOSPITAL
100 High St, Buffalo 14203
3495 Bailey Ave SUITE 901B, Buffalo 14215
VA MEDICAL CENTER
3495 Bailey Ave, Buffalo 14215
BUFFALO GENERAL HOSPITAL
100 High St, Buffalo 14203
Jacobs Neurological Institute
300 Essjay Rd SUITE 100, Buffalo 14221
Kaleida Health Buffalo General Hospital
100 High St, Buffalo 14203
Millard Fillmore Hospital
3 Gates Cir, Buffalo 14209
Education:
Medical School
Ohio State University / College of Medicine
Graduated: 1966
Montefiore Medical Center-Moses Division
Albany Medical Center Hospital
Brown University
U Of Med-Dentistry
Albert Einstein Coll Med
Harvard Med Sch Women's & Brigham Hosp


Edward Fine Photo 3

Goniometric Feedback Device And Method For Monitoring Angles Of Body Joints

US Patent:
4667685, May 26, 1987
Filed:
Sep 23, 1985
Appl. No.:
6/778807
Inventors:
Edward J. Fine - Williamsville NY
International Classification:
A61B 510
US Classification:
128782
Abstract:
A goniometric feedback device and an associated method for monitoring the relative angular position of two human body portions hinged at a common joint utilize a brace mechanism, transducer circuits, an array of selection light-emitting diodes (LEDs), an array of movement response LEDs, indicia associating with each LED array with a series of angular values, preselection circuits and sensing circuits. The brace mechanism includes two brace sections securable to the two body portions, and the transducer circuits provide an output electrical signal which varies in strength in response to a change in the relative angular position between the two brace sections so that the output signal strength corresponds to the relative angular position between the two brace sections. The preselection circuits permit one LED in the array of selection LEDs to be activated to indicate to a user a target angular displacement which the user subsequently attempts to achieve by moving the two body portions, and hence the two brace sections, relative to one another. The sensing circuits sense the strength of the output signal and activate an LED in the array of movement response LEDs which corresponds to the relative angular position of the two brace sections for providing information to the user of progress toward achieving target angular displacement.