DR. BRENT LANE NORRIS, M.D.
Medical Practice at 21 St, Tulsa, OK

License number
Oklahoma 25287
Category
Medical Practice
Type
Orthopaedic Trauma
Address
Address
2424 E 21St St SUITE 320, Tulsa, OK 74114
Phone
(918) 392-4547
(918) 392-4555 (Fax)

Professional information

Brent Norris Photo 1

Owner, Orthopaedic Trauma Services Of Oklahoma

Position:
Owner at Orthopaedic Trauma Services of Oklahoma
Location:
Tulsa, Oklahoma Area
Industry:
Medical Practice
Work:
Orthopaedic Trauma Services of Oklahoma since 2006 - Owner
Education:
Emory University 1980 - 1984
BA, Psychology/Chemistry
Skills:
Surgery, Healthcare, Medical Devices, Orthopedic, Clinical Research, Capital Equipment, Hospitals, Board Certified, Public Speaking, Medicine, Medical Education, Healthcare Management, Operating Room
Interests:
Travel, Futbol (especially European), NFL, NCAA Basketball, Woodworking, Golf, Tennis


Brent Norris Photo 2

Owner, Orthopaedic Trauma Services Of Oklahoma

Position:
Owner at Orthopaedic Trauma Services of Oklahoma
Location:
Tulsa, Oklahoma Area
Industry:
Medical Practice
Work:
Orthopaedic Trauma Services of Oklahoma since 2006 - Owner
Education:
Emory University 1980 - 1984
BA, Psychology/Chemistry
Skills:
Surgery, Healthcare
Interests:
Travel, Futbol (especially European), NFL, NCAA Basketball, Woodworking, Golf, Tennis


Brent Norris Photo 3

Orthopaedic Trauma Surgeon At Orthopaedic Trauma Services Oklahoma

Position:
Orthopaedic Trauma Surgeon at Orthopaedic Trauma Services Oklahoma
Location:
Tulsa, Oklahoma Area
Industry:
Medical Practice
Work:
Orthopaedic Trauma Services Oklahoma - Orthopaedic Trauma Surgeon


Brent L Norris Photo 4

Dr. Brent L Norris, Tulsa OK - MD (Doctor of Medicine)

Specialties:
Orthopedic Surgery
Address:
Orthopedic & Trauma Svs Of OK
2424 E 21St St STE 320, Tulsa 74114
(918) 392-4547 (Phone)
Certifications:
Orthopedic Surgery, 2010
Awards:
Healthgrades Honor Roll
Languages:
English
Hospitals:
Orthopedic & Trauma Svs Of OK
2424 E 21St St STE 320, Tulsa 74114
St. John Medical Center
1923 South Utica Ave, Tulsa 74104
Education:
Medical School
Medical College of Georgia
Graduated: 1989
Carolinas Med Center
University Of MD Med Sys
University Of Nc Hosps


Brent L Norris Photo 5

Brent L Norris, Tulsa OK

Specialties:
Orthopaedic Surgery, Orthopaedic Trauma
Work:
Orthopedic Hospital Of Oklahoma
2424 E 21St St, Tulsa, OK 74114
Education:
Medical College of Georgia (1989), University of North Carolina (1995) *Orthopaedic Surgery, Carolinas Medical Center (1996) *Orthopaedic Trauma


Brent Lane Norris Photo 6

Brent Lane Norris, Tulsa OK

Specialties:
Orthopedic Surgeon
Address:
2424 E 21St St, Tulsa, OK 74114
Board certifications:
American Board of Orthopaedic Surgery Certification in Orthopaedic Surgery


Brent Norris Photo 7

Low Profile Periarticular Tension Band Plating System With Soft Tissue Neutralization Cable Tunnel/Channel

US Patent:
2013009, Apr 11, 2013
Filed:
Oct 11, 2011
Appl. No.:
13/270870
Inventors:
Brent Lane Norris - Tulsa OK, US
Paul Ryan Stafford - Tulsa OK, US
Dana James Funk - Tulsa OK, US
International Classification:
A61B 17/88, A61B 17/80
US Classification:
606281, 606286
Abstract:
A bone plating system comprising: a plate, where the plate is low-profile and capable of contouring to a bone; a variable number of screw holes, locking or non-locking; at least one channel or tunnel through the plate; and at least one flexible device passing through the channel or tunnel and passing through soft tissue attached to the bone. The low profile plate, in combination with the flexible device passing through the surrounding soft tissue, functions as a tension band and acts to neutralize the muscle forces tending to pull the bone apart at a fracture. The low profile tension band plating system is targeted for periarticular tensile fractures for repair of patella, olecranon, greater trochanter, greater tuberosity, radial styloid, lateral or medial malleoli, or lateral malleolus.


Brent Norris Photo 8

Low Profile Periartiular Tension Band Plating System With Soft Tissue Neutralization Cable Tunnel/Channel For Use On The Greater Tuberosity Of The Humerus

US Patent:
2014003, Jan 30, 2014
Filed:
Oct 3, 2013
Appl. No.:
14/045197
Inventors:
Brent Lane Norris - Tulsa OK, US
Paul Ryan Stafford - Tulsa OK, US
Dana James Funk - Tulsa OK, US
International Classification:
A61B 17/80
US Classification:
606284
Abstract:
A bone plating system comprising: a plate, where the plate is low-profile and capable of contouring to a bone; a variable number of screw holes, locking or non-locking; at least one channel or tunnel through the plate; and at least one flexible device passing through the channel or tunnel and passing through soft tissue attached to the bone. The low profile plate, in combination with the flexible device passing through the surrounding soft tissue, functions as a tension band and acts to neutralize the muscle forces tending to pull the bone apart at a fracture. The low profile tension band plating system is targeted for periarticular tensile fractures for repair of the greater tuberosity of the humerus.


Brent Norris Photo 9

Low Profile Periartiular Tension Band Plating System With Soft Tissue Neutralization Cable Tunnel/Channel For Use On The Olecranon

US Patent:
2014003, Jan 30, 2014
Filed:
Oct 3, 2013
Appl. No.:
14/045147
Inventors:
Brent Lane Norris - Tulsa OK, US
Paul Ryan Stafford - Tulsa OK, US
Dana James Funk - Tulsa OK, US
International Classification:
A61B 17/80
US Classification:
606284
Abstract:
A bone plating system comprising: a plate, where the plate is low-profile and capable of contouring to a bone; a variable number of screw holes, locking or non-locking; at least one channel or tunnel through the plate; and at least one flexible device passing through the channel or tunnel and passing through soft tissue attached to the bone. The low profile plate, in combination with the flexible device passing through the surrounding soft tissue, functions as a tension band and acts to neutralize the muscle forces tending to pull the bone apart at a fracture. The low profile tension band plating system is targeted for periarticular tensile fractures for repair of the olecranon.